Skip to content

Since 2006 · Dubai, Doha and Damascus

Service & training

Ultrasound Probe Repair and Service

Inspection and repair for ultrasound probes: scratched, cracked or delaminated lenses, damaged cables, and the oil leaks and motor faults that affect 3D/4D probes.

Probe faults we repair

  • Scratched or cracked lenses
  • Lens delamination
  • Damaged or frayed cables
  • Oil leakage in 3D/4D probes
  • Oil seal problems
  • Motor faults in 3D/4D probes

Ultravision inspects and repairs ultrasound probes for hospitals and medical centres in the UAE. Technicians restore damaged lenses, repair and reinforce faulty cables, and fix oil seal and motor problems in 3D/4D probes. Whether a probe can be repaired depends on its type, its condition, the inspection results and technical feasibility.

Probe repairs we carry out

Lens repair

Scratches, cracks and delamination are repaired to restore the lens to its original condition and keep images clear.

Cable repair

Damaged or frayed cables are repaired and reinforced for a secure connection and uninterrupted signal transmission.

3D/4D probe oil leaks

Oil seal problems are resolved to stop leakage and prevent internal damage to the probe.

3D/4D probe motors

Motor faults are repaired to restore full rotational and mechanical movement in 4D probes.

How a probe repair works

  1. Take the probe out of use

    Stop using a probe with a damaged cable, and send us the probe type and a description of the fault.

  2. Inspection

    The probe is inspected to find the fault and confirm whether a repair is technically feasible.

  3. Repair

    The lens, cable, oil seal or motor is repaired with high-quality materials before the probe goes back into service.

Signs a probe needs inspection

  • Image quality has dropped
  • Performance is inconsistent
  • The cable is damaged or frayed
  • The lens is scratched, cracked or delaminating
  • The probe body shows wear or damage

Ultrasound Probe Service: questions

Ask our team a question
Can a damaged ultrasound probe be repaired?

Often, yes. Ultravision repairs probe lenses and cables, and the oil seals and motors of 3D/4D probes. Whether a particular ultrasound probe can be repaired depends on its type, its condition, the inspection results and technical feasibility.

What should I do if an ultrasound probe cable is damaged?

Stop using the probe straight away and contact Ultravision. The probe is inspected, then the damaged or frayed cable is repaired and reinforced to restore a secure connection and uninterrupted signal transmission, so the probe can be used safely again.

How can I tell if an ultrasound probe is failing?

Common signs are lower image quality, inconsistent performance and visible wear, such as a damaged cable, a scratched or cracked lens, or damage to the probe body. A professional inspection confirms the cause and whether the probe can be repaired.

How should ultrasound probes be looked after?

Clean each probe routinely, check it visually on a regular basis, and include probes in scheduled service checks of cable integrity and overall function. Regular ultrasound maintenance helps prevent unexpected failures and more costly repairs.

Which faults affect 3D/4D ultrasound probes?

Ultravision’s 3D/4D ultrasound probe repair covers oil leakage and motor faults. Oil seal problems are resolved to stop leaks and prevent internal damage, and the motor is repaired to restore full rotational and mechanical movement.

Arrange an ultrasound probe inspection

Send the make, model and serial number and a short description of the issue.

WhatsApp us (opens in a new tab)